The setup.img file is used to create a boot disk for the 7200 mainframe.  
The diskette must be a 720K floppy.  The disk can not be read using DOS.  The 
7200 uses PSOS as the OS.

Insert a 720K floppy.  The floppy must be free of media errors.  If running 
Windows 2000, just use rawwritewin. Select the target drive and the image file.

The diskette created is used to low format the hard drive in the 7200. 

The 7200 mainframe must use the Miniscribe 8425, 8425F or the Kalok KL320.  To
use the setup program, the drive MUST have NO physical errors.

Place the new disk into the 7200 and turn on the scope, or reset the scope.
Follow the menus to format the disk.

Do not reformat a disk that has errors or was already formatted!!



Kaylok Corporation
                                                 Disk Parameter Reference

 Model     Interface     Capacity    Cylinders      Heads   Sectors
 KL320     MFM           21MB        615            4       17

 Last address located for Kalok Corporation was 1289 Anvilwood Ave.
 Sunnyvale, CA 94089. Phone: (408)747-1315; Fax: (408)747-1319.




 ************************************************************
		 Miniscribe Disk Drive Specifications
				For
			    Model: 8425
     ************************************************************

     FORM FACTOR                            3.5 inch HH
     INTERFACE                              ST412/ST506
     DATA ENCODING METHOD                           MFM
     DATA TRANSFER RATE (Mbit/Sec)                  5.0

     DISK DRIVE CHARACTERISTICS
	HEADS                                         4
	CYLINDERS                                   615
	SECTORS/TRACK (512 Byte Sectors)             17
	UNFORMATTED BYTES/TRACK                  10,416
	RADIAL TRACK DENSITY (TPI)                  804
	ROTATIONAL SPEED (RPM)                    3,600
	UNFORMATTED CAPACITY (MBytes)              25.6
	FORMATTED CAPACITY (MBytes)                21.4

     ACCESS TIMES (mSec)*
	SINGLE TRACK                                 15
	ONE-THIRD STROKE**                           68
	MAXIMUM                                     150
     *(INCLUDES SETTLING)
     **(APPROXIMATION OF AVERAGE)

     POWER REQUIREMENTS
	DISSIPATION (Watts)
	   TYPICAL                                  9.9
	   MAXIMUM                                 13.0
	CURRENT (Amps)
	   +5 V DC (+ or - 5%)                      0.6
	   +12 V DC (+ or - 5%)                     0.7
	   MAXIMUM STARTUP CURRENT                  2.0

     PHYSICAL DIMENSIONS
	HEIGHT (in)                               1.625
	WIDTH (in)                                    4
	DEPTH (in)                                 5.75
	WEIGHT (lbs)                                1.8

     OPERATIVE ENVIRONMENTAL LIMITS
	MINIMUM TEMPERATURE (Centigrade)              4
	MAXIMUM TEMPERATURE (Centigrade)             50
	THERMAL GRADIENT (Degrees C/Hour)            10

     RELIABILITY
	MTBF (Hours)                             20,000
	MTTR (Minutes)                               30
	COMPONENT DESIGN LIFE (Years)                 5